RESEARCH USE ONLY. This page contains unit-conversion arithmetic only. It is not a dosing guide, not a protocol, and not a preparation or administration instruction for any person or animal. Products discussed on this site are supplied strictly for laboratory and research purposes.
GLOW is a three-peptide blend, and that is exactly what most pages covering it get wrong. Treating 70 mg as a single quantity and reporting one concentration is arithmetically meaningless here, because the three components are present at a fixed 10 : 10 : 50 ratio and therefore reach three different concentrations in the same solution.
What is actually in the vial
The product specification states the composition as three components in one vial: BPC-157 10 mg, TB-500 (Ac-LKKTETQ) 10 mg, GHK-Cu 50 mg — total peptide mass 70 mg, “co-lyophilised into a single vial at a fixed ratio of 10 mg : 10 mg : 50 mg.”
Concentration by solvent volume
| Bac water added | BPC-157 | TB-500 | GHK-Cu | mg in 10 units (BPC/TB/GHK) |
|---|---|---|---|---|
| 1 mL | 10 mg/mL | 10 mg/mL | 50 mg/mL | 1 / 1 / 5 |
| 2 mL | 5 mg/mL | 5 mg/mL | 25 mg/mL | 0.5 / 0.5 / 2.5 |
| 3 mL | 3.33 mg/mL | 3.33 mg/mL | 16.67 mg/mL | 0.33 / 0.33 / 1.67 |
| 5 mL | 2 mg/mL | 2 mg/mL | 10 mg/mL | 0.2 / 0.2 / 1 |
Worked example: reconstituted with 2 mL, the solution contains 5 mg/mL BPC-157, 5 mg/mL TB-500 and 25 mg/mL GHK-Cu. Twenty units is 0.2 mL, which contains 1.0 mg, 1.0 mg and 5.0 mg respectively. One number cannot describe this vial.
The syringe unit point almost every page gets wrong
An insulin syringe is graduated in units, which are a volume marking, not a mass. On both U-100 and U-50 insulin syringes, one unit corresponds to 0.01 mL. The difference is barrel capacity and gradation spacing — not the unit-to-volume relationship. Both are 100 units per millilitre.
The arithmetic is: mass = (component mg ÷ mL of solvent added) × (units × 0.01), run once per component.
Our reconstitution calculator handles a 44-compound library including blends.
What limits how long the solution lasts
Sourced fact: The Bacteriostatic Water for Injection label directs: “Do not store reconstituted solutions of drugs for injection unless otherwise directed by the manufacturer of the solute.” [1]
Inference: The widely-quoted 28-day figure describes the multiple-dose container of water, not what you dissolved in it. See where the 28-day rule actually comes from.
What this page is not
This is unit-conversion arithmetic for laboratory research planning. It is not medical or veterinary advice, not a protocol, not a recommendation of any volume, and not an instruction to administer anything to any person or animal.
A second thing worth stating plainly: no published study has tested this three-compound combination. The evidence base covers each peptide separately. We say so on the product page rather than implying the blend has been studied as a blend.
Reconstitution arithmetic for every compound in the catalogue: BPC-157 · TB-500 · Wolverine Stack · GLOW · KLOW · CJC-1295 / Ipamorelin · Ipamorelin · CJC-1295 No DAC · GHK-Cu · Epitalon · MOTS-c · AOD-9604 · NAD+ · PT-141 · Tesamorelin · Retatrutide · Tirzepatide · SS-31 · Selank · Semax · KPV · DSIP · PEG-MGF · FOXO4-DRI · ARA-290 · 5-Amino-1MQ
For researchers
GLOW blend · Bacteriostatic Water, USP · Reconstitution calculator · GLOW vs KLOW · Wolverine Stack arithmetic
RESEARCH USE ONLY — FULL DISCLAIMER. The products discussed on this page are supplied strictly for laboratory and scientific research purposes. They are not for human or veterinary use, and not for consumption. These statements have not been evaluated by the Food and Drug Administration. Nothing on this page is intended to diagnose, treat, cure, or prevent any disease in humans or animals. Nothing here constitutes medical or veterinary advice or a dosing, preparation, or administration recommendation for any person or animal.
References
- Hospira, Inc. Bacteriostatic Water for Injection, USP — SPL Set ID 87d6e9dc-fe3b-4593-ac9a-d7493d1959c7. NLM DailyMed.
- Composition figures quoted from the PureLab Performance GLOW product specification, verified 20 August 2026.